Product Description

PLC control cabinet
Product category: Variable frequency control cabinet
Zhikongda refers to a programmable control cabinet, which is a complete set of electrical cabinets that can control motors and switches. The Zhikongda PLC control cabinet has protection functions such as overload, short circuit, and phase loss protection
Control scheme of variable air volume butterfly valve for fume hood
Working principle of variable air volume control system: Variable air volume control is to adjust the supply and exhaust air volume of the system by adjusting the opening of the ventilation cabinet window and door in the laboratory, ensuring that no matter how the window opening is adjusted, the wind speed on the ventilation cabinet surface can always be accurately controlled to be 0.3-05m/s
Solution for variable air volume Venturi valve in fume hood
Variable air volume control system: Variable air volume control is achieved by adjusting the opening of ventilation cabinet windows and doors in the laboratory. Regardless of the adjustment of window opening, the system can always accurately control the wind speed on the ventilation cabinet surface to be 0.3-05m/s
UBC fume hood adaptive solution
Principle of UBC adaptive system: Based on VAV variable air volume, a detector is installed on the fume hood to monitor whether there is anyone moving in front of the fume hood. When someone is operating, a constant air inlet speed of 0.5m/s is maintained, and when there is no one, the air inlet speed is 0.3m/s. On the basis of VAV, energy consumption is greatly reduced again
Ventilation cabinet window lifting system
Working principle of the fume hood window lifting system: Based on the UBC adaptive system, by setting the window to automatically lower when the window automatically descends, the exhaust air volume of the fume hood is reduced to the minimum value, greatly reducing energy consumption again
PLC frequency conversion control system
The PLC frequency conversion control system automatically adjusts the operating frequency of the fan based on the detection of the switch signal of the fume hood, thereby achieving energy-saving and environmental protection effects while meeting safety requirements.
Accessory Surface wind speed sensor
Displacement sensor
Variable air volume butterfly valve
Variable air volume transparent butterfly valve
Variable air volume Venturi valve
Constant air volume Venturi valve
Variable air volume aluminum alloy valve
Pipeline static pressure controller/room differential pressure controller
Pressure sensor
There are sensors in the area

Control Scheme of Variable Air Volume Butterfly Valve for Fume HoodControl Scheme of Variable Air Volume Butterfly Valve for Fume HoodControl Scheme of Variable Air Volume Butterfly Valve for Fume HoodControl Scheme of Variable Air Volume Butterfly Valve for Fume HoodControl Scheme of Variable Air Volume Butterfly Valve for Fume HoodControl Scheme of Variable Air Volume Butterfly Valve for Fume HoodControl Scheme of Variable Air Volume Butterfly Valve for Fume Hood
 